產品簡述:SEVCON Gen4 Size 10 交流電機控制器 Operating voltage range at full current 50V to 800V
FEATURES
• AC Permanent Magnet synchronous motor
• AC Induction motor
• Up to 800V DC peak supply voltage
• Up to 300kW peak power output
• Up to 150kW continuous power output
• Advanced flux vector control
• Integrated logic circuit
• Includes an additional dedicated safety
supervisory processor
• 12V or 24V nominal supply
• Designed for ISO26262 ASIL C compliance
• Safety interlock pulsed enable signal
KEY PARAMETERS
• Operating voltage range at full current 50V to 800V
• Output motor phase current:
o 400A rms (2 min)
o 200A rms (Continuous)
• Water/Glycol coolant. Oil cooling available - contact Sevcon
• Safety:
o Electrical safety to ISO 6494, IEC 60664 and UL840
o Functional safety to ISO26262
o Pulsed safety enable input
o Pulsed status output
• Environmental:
o -40°C to +85°C operation
o IP6k9k and IP67 protection
o ISO 16750
• 12V or 24V nominal supply
• Weight: 10.9kg
M ULTIPLE MOTOR FEEDBACK OPTIONS
Gen4 Size 10 provides a number of motor feedback possibilities from a range of hardware
inputs and software control, allowing a great deal of flexibility.
• Absolute UVW encoder input
• Absolute Sin/Cos encoder input
• Incremental AB encoder input
• Resolver input
• Programmable 5V to 10V encoder power supply
INTEGRATED I/O
Gen4 Size 10 includes a fully-integrated set of inputs and outputs (I/0) designed to handle a
wide range of vehicle requirements. This eliminated the need for additional external I/O
modules or vehicle controllers and connectors.
• All I/O protected to 40V
• 4 analogue inputs 0-10V
• 4 digital inputs
• 3 power supplies 0-10V 100mA
• 3 digital outputs PWM max 2A
OTHER FEATURES
• A CANopen bus allows easy interconnection of controllers and devices such as
displays and driver controls.
• The CANbus allows the user to wire the vehicle to best suit vehicle layout since
inputs and outputs can be connected to any of the controllers on the vehicle and the
desired status is passed over the CAN network to the relevant motor controller.
• The Gen4 Size 10 controller can dynamically change the allowed battery current by
exchanging CAN messages with a compatible Battery Management System.
• Configurable as vehicle control master or motor slave.
ConFIGURATION TOOLS
Sevcon offers a range of configuration tools for
the Gen4 Size 10 controller, with options for
Windows based PC or calibrator handset unit.
These tools provide a simple yet powerful
means of accessing the CANopen bus for
diagnostics or parameter adjustment. The
handset unit features password protected
access levels and a customized logo start-up
screen.